LEVEL GAUGES | ||||||||||
Type | Model | PN rating | Max. press. |
Max. Temp. |
C to C (mm) |
Description | Data sheet | IOM | ||
Reflex | LG 40 | PN 40 | 32 barg | 239 ° C | 200 - 3100 | single / double isolating gauge valve with drain valve |
D-02-D-16270-EN-0 | D-02-B-16607-EN-0 | ||
Transparent | A1T / A2T (Glass-mica) |
PN 40 | 32 barg | 239 ° C | 250 - 1950 | single / double isolating gauge valve with drain valve, single/staggered multi section. LED illuminator |
D-03-D-19455-EN-1 | D-03-B-19703-EN-0 | ||
PN 63 | 50 barg | 265 ° C | ||||||||
PN 100 | 80 barg | 296 ° C | ||||||||
A1T / A2T ( Mica) |
PN 40 | 32 barg | 239 ° C | 360 - 1880 | single / double isolating gauge valve with drain valve, single/staggered multi section. LED illuminator |
D-03-D-19460-EN-1 | D-03-B-19705-EN-0 | |||
PN 63 | 50 barg | 265 ° C | ||||||||
PN 100 | 80 barg | 296 ° C | ||||||||
PN 160 | 100 barg | 312 ° C | ||||||||
PN 250 | 160 barg | 348 ° C | ||||||||
PN 320 | 200 barg | 367 ° C | 575 - 1580 | |||||||
Bi-colour | BU-A1T / A2T red-green (multiport) |
PN 63 | 50 barg | 265 ° C | 400- 880 | single / double isolating gauge valve with drain valve, single/staggered multi section. LED red-green illuminator. Special execution with tie bar or expansion loop |
D-04-D-16289-EN-1 | D-04-B-16615-EN-1 | ||
PN 100 | 80 barg | 296 ° C | ||||||||
PN 160 | 100 barg | 312 ° C | ||||||||
PN 250 | 160 barg | 348 ° C | ||||||||
PN 320 | 200 barg | 367 ° C | ||||||||
A1T / A2T red-green |
PN 40 | 32 barg | 239 ° C | 310 - 2110 | single / double isolating gauge valve with drain valve, single/staggered multi section. LED red-green illuminator. |
D-04-D-16285-EN-0 | D-04-B-16614-EN-0 | |||
PN 63 | 50 barg | 265 ° C | ||||||||
PN 100 | 80 barg | 296 ° C | ||||||||
A1T / A2T black-white |
PN 63 | 50 barg | 265 ° C | 350- 1110 | single / double isolating gauge valve with drain valve, single/staggered multi section. LED illuminator. |
D-04-D-19465-EN-1 | D-04-B-19785-EN-0 | |||
PN 100 | 80 barg | 296 ° C | ||||||||
PN 160 | 100 barg | 312 ° C | ||||||||
PN 250 | 160 barg | 348 ° C | ||||||||
PN 320 | 200 barg | 367 ° C | ||||||||
Remote - mechanical |
Type G | PN 40 - 320 | 32 - 200 barg |
40 ° C | 310 / 390 / 470 |
remote level transmission based on differential pressure of the boiler water level, with isolating gauge valve & illuminator. |
D-05-D-19300-EN-0 | D-05-B-21107-EN-0 | ||
Remote - electronic |
Type PE2-xx | PN 40 - 320 | 50 - 200 barg |
367 ° C | 300 - 1050 | electronic drum level indicator with primary element used in conjunction with electronic evaluating device ERW Lcd 2.0 |
D-05-D-19921-EN-1 | D-05-B-19923-EN-0 | ||
ERW Lcd 2.0 | LCD digital display - water level in %tage, with 4 to 20 mA outputs and 4 adjustable switchpoint output relays. |
|||||||||
LB 16 | LED bar chart indicator ( 0 - 100%) |
|||||||||
EL 65 | PN 40 | 32 barg | 239 ° C | conductivity sensor installed on primary element PE2-xx 8 to 28 pcs) |
||||||
EL 60 | PN 63 - 320 | 50 - 200 barg |
265 - 367 ° C |
MAGNETIC LEVEL GAUGE | ||||||||||
Type | Model | PN rating | Max. press. | Max. Temp. | C to C (mm) | Description | Data sheet | IOM | ||
indirect level gauge |
NA 7-50 | PN 6 | 5 barg | 159 ° C | custom design |
magnetic level indicator with red/white flap, drain and vent plug, accessories - magnetic switches (M510), remote level transmission ( MRK) |
D-06-D-20475-EN-0 | D-06-B-20482-EN-0 | ||
PN 10 | 8 barg | 175 ° C | ||||||||
PN 16 | 13 barg | 195 ° C | ||||||||
PN 25 | 20 barg | 214 ° C | ||||||||
NA 7-52 | PN 40 | 32 barg | 234 ° C | D-06-D-20478-EN-0 | ||||||
PN 63 | 50 barg | 265 ° C | ||||||||
accessories | M 510-1-60 | magnetic switches for signalling high & low level alarms |
D-06-D-16312-EN-0 | |||||||
MRK 1110-S | remote level transmission with 4 to 20 mA output signal |
D-06-D-16313-EN-0 |
FLOAT LEVEL SWITCH | ||||||||||
Type | Model | PN rating | Max. press. |
Max. Temp. | measu -ring range -W (mm) |
No. of swit- ches (M130) |
Description | Data sheet | IOM | |
Internal mounting |
RBJ54 | PN 16 | 13 barg | 195 ° C | 100 /150 | 2 | mounting flange DN 100, IP 54 housing (IP 65 on request) with low water test device |
D-07-D-16314-EN-0 | D-07-B-16632-EN-0 | |
PN 40 | 32 barg | 239 ° C | 100 /150 | |||||||
PN 63 | 50 barg | 265 ° C | 150 | |||||||
RBJ64 | PN 40 | 32 barg | 234 ° C | 250 | D-07-D-16315-EN-0 | .|||||
Type | Model | PN rating | Max. press. | Max..Temp. | measu -ring range -W (mm) |
No. of swit- ches (M130) |
C to C - A (mm) |
Low water level - D (mm) |
Data sheet | IOM |
External mounting with measuring chamber & drain valve, vessel connection : DN 20 / 25 |
BA 14 | PN 40 -100 | 32 - 80 barg | 239 - 296 ° C | 40 | 1 | 150 | 55 | D-07-D-16316-EN-0 | D-07-B-16633-EN-0 |
RBA 24 | PN 40 -100 | 32 - 80 barg | 239 - 296 ° C | 100 | 2 | 180 | 35 | D-07-D-16317-EN-0 | ||
150 | 340 | 120 | ||||||||
RBA 34 | PN 40 -100 | 32 - 80 barg | 239 - 296 ° C | 250 | 400 | 110 | D-07-D-16318-EN-0 | |||
350 | 500 | 100 | ||||||||
450 | 600 | |||||||||
550 | 700 | |||||||||
650 | 800 | |||||||||
750 | 900 | |||||||||
RBA 25 | PN 160 -320 | 100 - 200 barg | 312 - 367 ° C | 100 | 250 | 55 | D-07-D-16319-EN-0 | D-07-B-16634-EN-0 | ||
150 | 340 | 120 | ||||||||
RBA 35 | 250 | 400 | 110 | D-07-D-16320-EN-0 | ||||||
350 | 500 | 100 | ||||||||
450 | 600 | |||||||||
550 | 700 | |||||||||
650 | 800 | |||||||||
750 | 900 | |||||||||
External mounting - self monitoring water level limiter |
BA 75-1 with SMFC1 |
PN 160-320 | 100 - 200 barg | 312- 367 ° C | 20 | 1 | 340 | 120 | D-07-D-16321-EN-0 | |
accessories | M130 | magnetic switches for signalling high & low level alarms, pump On - Off |
D-07-D-16324-EN-0 |
ELECTRONIC LEVEL SWITCH | ||||||||||
Type | Model | PN rating | Max. press. | Max. Temp. | measuring range (mm) |
Description | Data sheet | IOM | ||
Level switch | LMC 1 | 230 VAC, 50 Hz, used with EL 041 EL 4-1, EL 914 | Low water level limiter with periodic self-checking |
D-08-D-16338-EN-0 | D-08-B-18997-EN-0 | |||||
Electrode | EL 041 | PN 40 | 32 barg | 239 0 C | 500 ~ 1500 | single conductivity electrode used with LMC 1 |
D-08-D-16333-EN-0 | |||
EL 4-1 | PN 320 | 200 barg | 367 ° C | 500 ~ 1500 | D-08-D-16334-EN-0 | |||||
Level switch | DHR 1 | 230 VAC, 50 Hz, used with EL 041 EL 4-1, EL 914 | Pump ON-OFF with high level alarm |
D-08-D-16339-EN-0 | ||||||
Level switch | DLR 1 | 230 VAC, 50 Hz, used with EL 041 EL 4-1, EL 914 | Pump ON-OFF with low level alarm |
|||||||
Electrode | EL 914 | PN 40 | 32 barg | 239 ° C | 500 ~ 1500 | multiple conductivity electrode used with DLR 1 / DHR 1 / LMC 1 |
D-08-D-16337-EN-0 | |||
Level switch | SMLC 1 | 230 VAC, 50 Hz, used with EL 030, EL 19-2 | Self-monitoring low water level limiter with periodic self-checking |
D-08-D-16329-EN-0 | D-08-B-16644-EN-1 | |||||
Electrode | EL 030 | PN 40 | 32 barg | 239 ° C | 500 ~ 1500 | Self-monitoring single conductivity electrode used with SMLC 1 |
D-08-D-16325-EN-0 | |||
EL 19-2 | PN 320 | 200 barg | 367 ° C | 500 ~ 1500 | D-08-D-16328-EN-0 | |||||
Level switch | SMHC 1 | 230 VAC, 50 Hz, used with EL 040, EL 21-2 | Self-monitoring high water level limiter with periodic self-checking |
D-08-D-16332-EN-0 | D-08-B-16645-EN-1 | |||||
Electrode | EL 040 | PN 40 | 32 barg | 239 ° C | 500 ~ 1500 | Self-monitoring single conductivity electrode used with SMHC 1 |
D-08-D-16330-EN-0 | |||
EL 21-2 | PN 320 | 200 barg | 367 ° C | 500 ~ 1500 | D-08-D-16331-EN-0 | |||||
Level transmitter | DLT 1 | 230 VAC, 50 Hz, used with EC 6 | level transmitter with 4 to 20 mA output |
D-08-D-16342-EN-0 | D-08-B-16790-EN-1 | |||||
Electrode | EC 6 | PN 40 | 32 barg | 239 ° C | 170 ~ 1200 | capacitance electrode used with DLT 1 |
D-08-D-16341-EN-0 |
TDS CONTROL SYSTEM | ||||||||||
Type | Model | PN rating | Max. press. | Max. Temp. | measuring range (mm) |
Description | Data sheet | IOM | ||
Controller | FLB 1 | 230 VAC, 50 Hz, used with EL 18, EL 22, EL 23 | TDS conductivity controller |
D-08-D-16346-EN-0 | D-08-B-21674-EN-0 | |||||
Sensor | EL 18 | PN 40 | 32 barg | 239 ° C | 41 | conductivity sensor for wafer mounting - DN 15 ~ 40 |
D-08-D-16343-EN-0 | |||
EL 22 | PN 40 | 32 barg | 239 ° C | 170 (min) | Conductivity sensor for T-piece mounting |
D-08-D-16344-EN-0 | ||||
EL 23 | PN 63 /100 | 50 /80 barg | 265 / 296 ° C | 500 (max) | Conductivity sensor with measuring chamber |
D-08-D-16345-EN-0 |
BOTTOM BLOWDOWN VALVE | ||||||||||
Type | Model | PN rating | Max. press. | Max. Temp. |
Size | Description | Data sheet | IOM | ||
Blowdown valve |
KAV1 R1-N | PN 40 | 32 barg | 239 ° C | DN 20 ~ 50 | rapid action intermittent boiler blowdown valve with manual hand lever |
D-09-D-16365-EN-0 | D-09-B-21687-EN-0 | ||
KAV1 R1-N | PN 63 | 50 barg | 265 ° C | DN 25 & 40 | ||||||
Blowdown valve ( auto) |
KAV2 R1-N | PN 40 | 32 barg | 239 ° C | DN 20 ~ 50 | rapid action intermittent boiler blowdown valve with manual hand lever and pneumatic actuator |
||||
KAV2 R1-N | PN 63 | 50 barg | 265 ° C | DN 25 & 40 | ||||||
accessories | PGM 1 | G 1/4” brass 3/2 solenoid valve, 230 VAC 50 Hz for air as medium | 3/2 way solenoid valve with integrated cycling timer used with KAV2 R1-N |
Allied Energy Systems Pte Ltd
66 Tannery Lane#02-03A Sindo Building
Singapore 347805 Republic of Singapore
Email: info [at] aes-singapore [dot] com
Tel: (+65) 6744 8769 Fax: (+65) 6746 0080
©2013 by Allied Energy Systems Pte Ltd. All rights reserved.